Tipo de membrana: Regenerated Cellulose
Characteristics: Hydrophilic membrane with good solvent resistance, extremely low non-specific binding. Compatible with nearly all common HPLC solvents. Tolerates aqueous samples in the pH range of 3-12
Applications: Membrane of choice for low nonspecific binding applications. Tissue Culture media filtration and general biological sample preparations.
Regenerated Cellulose membranes are particularly suitable for the filtration of tissue culture media and general biological sample filtration due to it's low non-specific binding characteristics for proteins.
Número de GC |
Descriptioni |
Diámetro
(mm) |
Tamaño de Poro (µm) |
Pre-Filtro |
Material de la Cubierta |
Estéril |
Conexiones
Entrada / Outle |
5078020D |
FRC150020 |
15 |
0.2 |
- |
USV |
- |
LLF / LSM |
5120145D |
FRC140020 |
15 |
0.2 |
- |
USV |
- |
LLF / Mini Tip |
5078022D |
FRC150045 |
15 |
0.45 |
- |
USV |
- |
LLF / LSM |
5078019D |
FRC140045 |
15 |
0.45 |
- |
USV |
- |
LLF / Mini Tip |
5078021D |
FRC150020S |
15 |
0.2 |
- |
USV |
yes |
LLF / LSM |
5078023D |
FRC150045S |
15 |
0.45 |
- |
USV |
yes |
LLF / LSM |
5123554D |
FRC140020S |
15 |
0.2 |
- |
USV |
yes |
LLF / Mini |
5126249D |
FRC140045S |
15 |
0.45 |
- |
USV |
yes |
LLF / Mini |
5078026D |
FRC250020 |
25 |
0.2 |
- |
USV |
- |
LLF / LSM |
5078032D |
FRC250045 |
25 |
0.45 |
- |
USV |
- |
LLF / LSM |
5078028D |
FRC250020S |
25 |
0.2 |
- |
USV |
yes |
LLF / LSM |
5078034D |
FRC250045S |
25 |
0.45 |
- |
USV |
yes |
LLF / LSM |
5078029D |
FRC250020R |
25 |
0.2 |
- |
RV |
- |
LLF / LSM |
5078035D |
FRC250045R |
25 |
0.45 |
- |
RV |
- |
LLF / LSM |
5078030D |
FRC250020RS |
25 |
0.2 |
- |
RV |
yes |
LLF / LSM |
5078036D |
FRC250045RS |
25 |
0.45 |
- |
RV |
yes |
LLF / LSM |
5078031D |
FRC250020RV |
25 |
0.2 |
yes |
RV |
- |
LLF / LSM |
5078037D |
FRC250045RV |
25 |
0.45 |
yes |
RV |
- |
LLF / LSM |
|
FRC250020RVS |
25 |
0.2 |
yes |
RV |
yes |
LLF / LSM |
|
FRC250045RVS |
25 |
0.45 |
yes |
RV |
yes |
LLF / LSM |
5120248D |
FRC300020 |
30 |
0.2 |
- |
USV |
- |
LLF / LSM |
5078054D |
FRC300045 |
30 |
0.45 |
- |
USV |
- |
LLF / LSM |
5121017D |
FRC300020S |
30 |
0.2 |
- |
USV |
yes |
LLF / LSM |
|
FRC300045S |
30 |
0.45 |
- |
USV |
yes |
LLF / LSM |
5078052D |
FRC300020R |
30 |
0.2 |
- |
RV |
- |
LLF / LSM |
5078055D |
FRC300045R |
30 |
0.45 |
- |
RV |
- |
LLF / LSM |
|
FRC300020RS |
30 |
0.2 |
- |
RV |
yes |
LLF / LSM |
|
FRC300045RS |
30 |
0.45 |
- |
RV |
yes |
LLF / LSM |
5078053D |
FRC300020RV |
30 |
0.2 |
yes |
RV |
- |
LLF / LSM |
5078056D |
FRC300045RV |
30 |
0.45 |
yes |
RV |
- |
LLF / LSM |
|
FRC300020RVS |
30 |
0.2 |
yes |
RV |
yes |
LLF / LSM |
|
FRC300045RVS |
30 |
0.45 |
yes |
RV |
yes |
LLF / LSM |
LLF: Luer lock Female
LSM: Luer Slip Male
USV: Ultrasonic Welded Version
RV: Ring Version Utilice nuestra Búsqueda para encontrar el producto que necesita hoy. Si necesita ayuda, no dude en comunicarse con nuestro departamento de Servicio al Cliente, llamando al 800.669.6905, o comuníquese con nuestro Representante de Ventas local.
Los filtros para jeringas Graphic Controls tienen una historia de más de 15 años. En 1996, Dia-Nielsen se integró con Schleicher & Schuell y en 1999 se expandió para incluir la producción de filtros descartables para las ciencias de la vida, ofreciendo filtros para jeringas estándar para aplicaciones de partículas y microscópicas. En 2011 Graphic Controls adquirió e integró a Dia-Nielsen, lo que nos permite ofrecer una línea completa de filtros para jeringas de alta calidad. En 2013, Graphic Controls completó la construcción de instalaciones limpias haciendo posible el traslado de la producción de filtros para jeringas a los Estados Unidos.
|
Los productos de filtración de Graphic Controls son para usar en aplicaciones industriales y en laboratorios eg. preparación de pruebas, monitoreo ambiental, análisis de fluidos, filtración y cromatografía. Los productos de filtración de Graphic Controls no son para el uso humano.
|