Tipo de membrana: Cellulose Acetate
Characteristics: Low protein binding, ideal for aqueous based samples. High protein recovery from filtration. Lower protein binding compared to PVDF.
Applications: Tissue culture media filtration, Sensitive biological samples
.
Cellulose Acetate membranes are used in tissue culture media filtration as well as sensitive biological samples. They have low protein absorption and can be used in the clear filtration and sterile filtration of aqueous solutions. High temperature stability.
Número de GC |
Descriptioni |
Diámetro
(mm) |
Tamaño de Poro (µm) |
Pre-Filtro |
Material de la Cubierta |
Estéril |
Conexiones
Entrada / Outle |
5123280D |
FCA150020 |
15 |
0.2 |
- |
USV |
- |
LLF / LSM |
5123453D |
FCA140020 |
15 |
0.2 |
- |
USV |
- |
LLF / Mini Tip |
5077002D |
FCA150045 |
15 |
0.45 |
- |
USV |
- |
LLF / LSM |
5123456D |
FCA140045 |
15 |
0.45 |
- |
USV |
- |
LLF / Mini Tip |
5123091D |
FCA150020S |
15 |
0.2 |
- |
USV |
yes |
LLF / LSM |
|
FCA150045S |
15 |
0.45 |
- |
USV |
yes |
LLF / LSM |
|
FCA140020S |
15 |
0.2 |
- |
USV |
yes |
LLF / Mini |
|
FCA140045S |
15 |
0.45 |
- |
USV |
yes |
LLF / Mini |
5077007D |
FCA250020 |
25 |
0.2 |
- |
USV |
- |
LLF / LSM |
5077010D |
FCA250045 |
25 |
0.45 |
- |
USV |
- |
LLF / LSM |
5120518D |
FCA250020S |
25 |
0.2 |
- |
USV |
yes |
LLF / LSM |
5123031D |
FCA250045S |
25 |
0.45 |
- |
USV |
yes |
LLF / LSM |
5077008D |
FCA250020R |
25 |
0.2 |
- |
RV |
- |
LLF / LSM |
5077013D |
FCA250045R |
25 |
0.45 |
- |
RV |
- |
LLF / LSM |
5077009D |
FCA250020RS |
25 |
0.2 |
- |
RV |
yes |
LLF / LSM |
5077014D |
FCA250045RS |
25 |
0.45 |
- |
RV |
yes |
LLF / LSM |
|
FCA250020RV |
25 |
0.2 |
yes |
RV |
- |
LLF / LSM |
5126244D |
FCA250045RV |
25 |
0.45 |
yes |
RV |
- |
LLF / LSM |
5120357D |
FCA250020RVS |
25 |
0.2 |
yes |
RV |
yes |
LLF / LSM |
|
FCA250045RVS |
25 |
0.45 |
yes |
RV |
yes |
LLF / LSM |
5077027D |
FCA300020 |
30 |
0.2 |
- |
USV |
- |
LLF / LSM |
5077028D |
FCA300045 |
30 |
0.45 |
- |
USV |
- |
LLF / LSM |
5122117D |
FCA300020S |
30 |
0.2 |
- |
USV |
yes |
LLF / LSM |
5120389D |
FCA300045S |
30 |
0.45 |
- |
USV |
yes |
LLF / LSM |
5121824D |
FCA300020R |
30 |
0.2 |
- |
RV |
- |
LLF / LSM |
|
FCA300045R |
30 |
0.45 |
- |
RV |
- |
LLF / LSM |
|
FCA300020RS |
30 |
0.2 |
- |
RV |
yes |
LLF / LSM |
|
FCA300045RS |
30 |
0.45 |
- |
RV |
yes |
LLF / LSM |
|
FCA300020RV |
30 |
0.2 |
yes |
RV |
- |
LLF / LSM |
|
FCA300045RV |
30 |
0.45 |
yes |
RV |
- |
LLF / LSM |
|
FCA300020RVS |
30 |
0.2 |
yes |
RV |
yes |
LLF / LSM |
|
FCA300045RVS |
30 |
0.45 |
yes |
RV |
yes |
LLF / LSM |
LLF: Luer lock Female
LSM: Luer Slip Male
USV: Ultrasonic Welded Version
RV: Ring Version
Utilice nuestra Búsqueda para encontrar el producto que necesita hoy. Si necesita ayuda, no dude en comunicarse con nuestro departamento de Servicio al Cliente, llamando al 800.669.6905, o comuníquese con nuestro Representante de Ventas local.

Los filtros para jeringas Graphic Controls tienen una historia de más de 15 años. En 1996, Dia-Nielsen se integró con Schleicher & Schuell y en 1999 se expandió para incluir la producción de filtros descartables para las ciencias de la vida, ofreciendo filtros para jeringas estándar para aplicaciones de partículas y microscópicas. En 2011 Graphic Controls adquirió e integró a Dia-Nielsen, lo que nos permite ofrecer una línea completa de filtros para jeringas de alta calidad. En 2013, Graphic Controls completó la construcción de instalaciones limpias haciendo posible el traslado de la producción de filtros para jeringas a los Estados Unidos.
|